Регистрация
deal.by
Frequency Converter with Trip Values KFD2-UFC-1.D - фото 1 - id-p95222030
Характеристики и описание

Техническая спецификация в PDF  

Описание оборудования

24 V DC

General specifications

Signal typeDigital Input

Functional safety related parameters

Safety Integrity Level (SIL)SIL 2

Supply

Connectionterminals 23+, 24- or power feed module/Power Rail
Rated voltage20 ... 30 V DC
Rated currentapprox. 100 mA
Power dissipation/power consumption? 2 W / 2.2 W

Interface

Programming interfaceprogramming socket

Input

Connection sidefield side
ConnectionInput I: 2-wire sensor: terminals 1+, 3- three wire sensИли отправьте нам запрос на
input II: terminals 13+, 14- start-up override;
Input I2- or 3-wire sensor, sensor acc. to EN60947-5-6 (NAMUR) or mechanical contact
Input IIstartup override: 1 ... 1000 s, adjustable in steps of 1 s

Output

Connection sidecontrol side
Connectionoutput I: terminals 10, 11, 12
output II: terminals 16, 17, 18
outout III: terminasl 19+, 20-
output IV: terminals 8+, 7-
Output I, IIsignal, relay
Output IIIelectronic output, passive
Output IVanalog
Collective error messagePower Rail

Transfer characteristics

Input I
Output I, II
Output IV

Galvanic isolation

Input I/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I, II/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Mutual output I, II, IIIreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output III/power supply and collective errorbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Output III/IVbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Output IV/power supply and collective errorfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Start-up override/power supply and collective errorfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Interface/power supply and collective errorfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Interface/output IIIbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff

Indicators/settings

Display elementsLEDs , display
Control elementsControl panel
Configurationvia operating buttons
via PACTware
Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility
Low voltage

Conformity

Electromagnetic compatibilityNE 21:2006
Degree of protectionIEC 60529:2001

Ambient conditions

Был online: Давно
OOO "ФилФар Технолоджи"
Рейтинг не сформирован
10 лет на Deal.by

Frequency Converter with Trip Values KFD2-UFC-1.D

Под заказ
Цену уточняйте
Доставка
Оплата и гарантии